Oil-immersed voltage-regulating transformer
1. Features 7-position on-load tap changing, allowing for voltage adjustment under load to ensure a stable low-voltage output—ideal for power grids with significant voltage fluctuations.
2. Utilizes an ONAN (oil-immersed, natural-air-cooled) design; with no rotating auxiliary equipment, it requires minimal maintenance and offers high operational reliability.
3. Undergoes comprehensive testing in accordance with national standards; features robust insulation and short-circuit resistance, along with excellent sealing to minimize the risk of oil leaks.
4. Backed by one-stop technical support directly from the manufacturer, including assistance with project bidding and on-site installation guidance.
Product Name: Oil-Immersed Voltage-Regulating Transformer
Product Model: S-500/44
Rated Capacity: 500 kVA
Rated Frequency: 50 Hz
Connection Group: YN0d11
Cooling Method: ONAN (Oil-Immersed Natural Cooling)
Impedance Voltage: 8.4%
Insulation Level: L200 AC95 / AC5
Manufacturing Standards: GB 1094.1 "Power Transformers – Part 1: General"; GB/T 6451 "Technical Parameters and Requirements for Oil-Immersed Power Transformers"
Structural Design Specifications
1. Core: Constructed from high-permeability, cold-rolled, grain-oriented silicon steel sheets using a stepped-lap lamination process to minimize no-load losses and noise. The core is securely clamped, ensuring high mechanical strength and minimal vibration during operation.
2. Windings: High- and low-voltage windings are fabricated using high-quality insulated conductors with a layered insulation structure. Following vacuum drying and oil impregnation, the windings exhibit stable insulation performance and robust resistance to short-circuit forces, enabling them to withstand sudden short-circuit current surges.
3. Tank and Cooling System: The welded steel tank is equipped with external corrugated radiators, utilizing the natural convection of transformer oil for heat dissipation—a configuration known as ONAN (Oil-Natural, Air-Natural) cooling. The absence of rotating components, such as fans or oil pumps, reduces potential points of failure. All tank welds undergo leak testing to ensure a reliable seal, effectively preventing oil leakage and moisture ingress.
4. On-Load Tap Changer (OLTC): An integrated 7-position on-load tap changer allows for tap adjustments while the transformer is under load. This enables real-time compensation for voltage fluctuations on the high-voltage side, ensuring a stable output voltage on the low-voltage side. The tap changer features a wear-resistant, arc-extinguishing design that effectively suppresses switching arcs, thereby extending the equipment's service life.
5. Accessories
High-voltage and low-voltage bushings: Porcelain-insulated bushings that are resistant to contamination and outdoor environmental aging; they serve to route high- and low-voltage leads while isolating live components.
Oil level gauge: Provides a clear, visual indication of the oil level within the tank, facilitating routine inspections by maintenance personnel.
Pressure relief valve: Automatically releases pressure in the event of a sudden internal fault, protecting the tank structure and preventing the equipment from rupturing.
Temperature monitoring components: Includes provisions for temperature sensing, allowing for remote monitoring of the top-oil temperature and real-time tracking of the equipment's operating temperature rise.
Oil drain valve and oil filling port: Designed for convenient on-site oil filling, oil sampling for laboratory analysis, and draining the oil during maintenance.
Applicable Operating Conditions and Usage Requirements
1. Installation Environment: Suitable for both indoor and outdoor installation; ideal for industrial plants, mining power distribution, new energy stations, and overseas power transmission and distribution projects.
2. Environmental Requirements: Ambient temperature range of -20°C to +40°C; altitude not exceeding 1,000m (customization available for high-altitude applications); suitable for installation sites with relative humidity ≤85%, free from corrosive gases and severe vibration.
3. Operating Medium: Uses high-quality mineral transformer oil for insulation, cooling, and arc-extinguishing functions; vacuum oil filling is performed prior to delivery to minimize air bubbles and ensure insulation strength.
Protection Features: Supports external relay protection devices; configured with overcurrent, instantaneous trip, and gas (Buchholz) protection to enable fault tripping and alarm functions.
Factory Testing
Each transformer undergoes a full suite of tests in accordance with national standards prior to delivery. Tests include winding DC resistance, voltage ratio and vector group verification, insulation resistance, power-frequency withstand voltage, induced withstand voltage, no-load loss, load loss, and partial discharge detection. A comprehensive factory test report is issued to meet domestic project acceptance and overseas project inspection requirements.