110kV GIS Switchgear
1. Compact footprint: Significantly smaller in size compared to traditional open-type AIS switchgear, making it ideal for urban underground substations and projects with limited land availability.
2. High operational reliability: All high-voltage live components are sealed within metal enclosures, protecting them from rain, snow, dust, pollution, and condensation, resulting in a low failure rate.
3. Minimal maintenance: Internal components are shielded from environmental degradation; routine maintenance is limited to monitoring SF₆ gas density, eliminating the need for frequent contact inspections.
4. Strong environmental adaptability: Suitable for high-altitude, coastal (salt spray), extreme cold, high-temperature, and heavily polluted regions; can be installed both indoors and outdoors.
5. Factory pre-assembly: Modules are assembled and tested at the factory, with only interconnection and gas filling required on-site, drastically reducing installation time.
6. High safety: The metal enclosure is fully grounded with no exposed live parts, ensuring operator safety; equipped with explosion-proof pressure relief devices to safeguard the equipment in the event of a fault.
This is a complete, fully enclosed SF₆ gas-insulated high-voltage switchgear assembly. It houses the circuit breaker, three-position disconnector, earthing switch, current transformer (CT), voltage transformer, and busbars within a grounded metal tank filled with sulfur hexafluoride (SF₆) gas, which provides insulation and arc-extinguishing capabilities.
1. Key Parameters
Rated voltage: 126 kV (110 kV system)
Rated current: Up to 4000 A
Rated short-circuit breaking current: 50 kA
Mechanical endurance: 10,000 operations; electrical endurance: 20 operations
Applications: Indoor and outdoor substations; suitable for high-altitude, high-temperature/high-humidity, sandy/dusty, and extreme cold environments.
2. Structural Components (refer to image)
Angled/vertical components on the left: Outlet bushings (insulating bushings) for high-voltage output, connecting to cables or overhead lines.
Gray cylindrical tanks: Individual SF₆ gas compartments separated by flanges with yellow sealing rings; these segregate the gas chambers for the circuit breaker, disconnector, and busbars.
Square boxes above/on the side of the tanks: Operating mechanism cabinets controlling the opening and closing of circuit breakers and disconnectors.
Integrated steel base at the bottom: A unified mounting base for the entire assembly, allowing for factory pre-assembly and on-site installation as a complete unit.
3. Functions: Enables closing, opening, short-circuit fault protection, and earthing/isolation for maintenance within the 110 kV power grid; supports automatic reclosing; used for power distribution, protection, and control in substations.